Vue de la page 0
Owner's Guide
Printed in China
Toll Free 1 866 295 6775
www.PowerBright.com
WARNING:
This Unit employs Components that tend to produce arcs or sparks – To
prevent fire or explosion, do not install in compartments containing
batteries or flammable materials - SHOCK HAZARD. DO NOT OPEN.
CAUTION:
OUTPUT NON-SINUSOIDAL REFER TO MANUAL - Provided with integral
protection against overloads. To Prevent fire, do not cover or obstruct
ventilation openings. Do not mount in Zero-Clearance compartment.
Overheating may result. For continued protection against risk of fire,
replace only with the same type and fuse rating: 8A
Notice :
The output of this device is not sinusoidal. It has a total harmonic distortion
of 30% percent and maximum single harmonic of 8 percent
XR400
XR750
3149458
Conforms to UL Std. 458
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - Owner's Guide

Owner's Guide Printed in ChinaToll Free 1 866 295 6775www.PowerBright.comWARNING:This Unit employs Components that tend to produce arcs or spark

Page 2 - 1 Introduction

86 Inverter Operation1. When properly connected to a 12V outlet, and when the ON/OFF switch is in the ON position, the light will glow BLUE, indica

Page 3 - Warnings and Cautions

9• If an AC product rated higher than 400/750 is plugged into the XR400/750, the inverter will shut down. The RED FAULT light comes on.• If the XR400/

Page 4 - CAUTION: Risk of Fire

10• In the event of an overload, low battery voltage oroverheating, the XR400 / XR750 automaticallyshuts down.Battery Operating TimeOperating time wil

Page 5 - XR400 / XR750

11Interference with Electronic EquipmentGenerally, most AC products operate with XR400/750just as they would with household AC power.Below is informat

Page 6 - 3 Safety Features

127 TroubleshootingPROBLEM: AC product will not operate, no inverterlights are ON.PROBLEM: Measured inverter output is too low.Possible cause Solution

Page 7 - 4 Inverter Features

13PROBLEM: AC product will not operate, RED FAULTlight ON.Battery voltage is too low. Recharge battery.Possible cause SolutionAC product(s) connecteda

Page 8 - 5 Using the Inverter

14Specifications are subject to change without notice.AC Power OutputUSB Power Outpu tAC output voltage (nominal)Continuous AC output powerPeak AC out

Page 9

15DC PowerPhysicalDC input voltage range (VDC)12.5V DC, 40A Max 12.5V DC, 75A MaxBattery drain with no AC load (at 12 V input)0.4AEfficiency (maximum)

Page 10 - 6 Inverter Operation

169 Warranty and ReturnWarrantyWhat does this warranty cover? This Limited Warrantyis provided by PowerBright ("PowerBright") andcovers defe

Page 11

17shipment to the customer, whichever is greater. All replacedproducts and all parts removed from repaired productsbecome the property of PowerBright.

Page 12 - Battery Operating Time

2 Important Safety InformationMisusing or incorrectly connecting theXR400/750may damage the equipment or create hazardousconditions for users. Read th

Page 13 - XR400/750

18What does this warranty not cover? This LimitedWarranty does not covernormal wear and tear of the productor costs related to the removal, installati

Page 14 - 7 Troubleshooting

20ExclusionsIf this product is a consumer product, federal law does notallow an exclusion of implied warranties. To the extent youare entitled to impl

Page 15 - AC product(s) connected

21Return Material Authorization PolicyBefore returning a product directly to PowerBright you mustobtain a Return Material Authorization (RMA) number a

Page 16 - USB Power Outpu t

22Return Procedure1. Package the unit safely, preferably using the originalbox and packing materials. Please ensure that yourproduct is shipped fully

Page 17 - DC Power

2The XR400 / XR750 housing may becomeuncomfortably warm, reaching 140° F (60° C) underextended high power operation. During operation,keep it away fro

Page 18 - 9 Warranty and Return

2CAUTION: Risk of Fire.Do not replace any vehicle fuse with a rating higher than recommended by the Vehicle Manufacturer. Ensure that the electrical s

Page 19

3CAUTION: Output non-sinusoidalSome chargers for small nickel-cadmium batteriescan be damaged if connected to the XR400 / XR750Do not use the inverter

Page 20

4Additional Safety Guidelines• Do not insert foreign objects in theXR400/750 outlets or other openings.• Never connect the inverter to power utility A

Page 21 - Warning: Limitations On Use

54 Inverter FeaturesFigure 1Features and AccessoriesPowerBright® XR400/750Power/Fault lightUSB portPower input TerminalsOn/Off SwitchAC OutletsVentila

Page 22

65 Using the InverterThrough its AC outlet, theXR400/750 is capable of powering most 120V AC products that use400W/750W or less. The XR400/750 can als

Page 23 - Return Procedure

71. Plug a DC cable into the DC cable port on theXR400/750 and connect to a 12V battery.Observe correct polarity. 2. Plug the device you want to o